Phase-plane layers

Layers use the current applied current. The trajectory can include earlier current values.

Shows the last 0–500 ms of model time in the phase plane. Set 0 to show only the current state. Independent of playback speed and the trace window.

Equilibria: ● stable (filled circle), ○ unstable (open circle), ◇ saddle (open diamond). These classify local linear stability.

Arrows show direction in plot coordinates; their lengths do not represent speed.

1× = 1 ms of model time per ms of playback. Slow playback preserves the integration time step.

Cellular biophysics · NSCI 351

Morris–Lecar Simulator

0 ms

Phase plane Click to set V and w (0–1) · nullclines show zero derivatives

━ Trajectory / ● current state━ dV/dt = 0━ dw/dt = 0

Membrane voltage V (mV)

Potassium activation w

Applied current I (µA/cm²)

Running. Applied-current changes preserve state and history.

Try this in class

  1. Choose Type I below onset, then slow firing. Use the near-rest phase view to find the bottleneck where the nullclines nearly touch.
  2. For Type I, increase I from 40 to 45 µA/cm². The firing rate rises from a very low value.
  3. Compare Type II at I = 88 and 90 µA/cm². Repetitive firing starts at a finite frequency; the near-onset orbit already has a substantial period-to-period rate.
  4. Choose Type II depolarization block at I = 250 µA/cm². After the transient, compare the stable depolarized equilibrium with repetitive firing at I = 100 µA/cm².
  5. Pause and click either side of a nullcline. Predict the initial direction. A nullcline intersection is an equilibrium; its stability matters.
  6. Choose Type I below onset (I = 39 µA/cm²), then enable the saddle manifolds. The stable manifold is the local separatrix: nearby trajectories on opposite sides can have different excursions. The unstable branches leave the saddle in forward time.
Model & parameters

The reduced Morris–Lecar model describes membrane voltage V (mV) and potassium activation w (dimensionless, 0–1). Calcium activation is assumed to equilibrate instantaneously: m=m∞(V). An applied current density Iapp (µA/cm²) drives the membrane.

Membrane and recovery equations

CdVdt=Iapp−gCam∞(V)(V−ECa)−gKw(V−EK)−gL(V−EL)
dwdt=w∞(V)−wτw(V)

The three ionic terms are calcium, potassium, and leak current densities (µA/cm²). Each is a conductance density multiplied by its driving voltage. The potassium gate relaxes toward its voltage-dependent steady state.

Steady-state activation

m∞(V)=1+tanh(V−V1V2)2
w∞(V)=1+tanh(V−V3V4)2

The potassium relaxation time is τw(V)=1φcosh(V−V32V4) (ms). The parameters V1 and V3 set half-activation voltages; V2 and V4 set activation slopes.

Parameter sets used by the starting examples

These are the preset values; sliders modify the active simulation. Type I examples illustrate gradual frequency onset near a saddle-node on an invariant circle (SNIC). Type II examples illustrate finite-frequency onset in a Hopf regime, with initial-condition dependence near onset.

SymbolMeaningType IType IIUnits
CMembrane capacitance2020µF/cm²
gCaCalcium conductance44.4mS/cm²
gKPotassium conductance88mS/cm²
gLLeak conductance22mS/cm²
ECaCalcium reversal potential120120mV
EKPotassium reversal potential−84−84mV
ELLeak reversal potential−60−60mV
V1Calcium half-activation voltage−1.2−1.2mV
V2Calcium activation slope1818mV
V3Potassium half-activation voltage122mV
V4Potassium activation slope17.430mV
φPotassium rate factor0.0670.04ms⁻¹

Applied current density: Type I examples use 39, 40, or 45 µA/cm²; Type II examples use 0, 88, 90, 100, or 250 µA/cm². The 250 µA/cm² example demonstrates depolarization block.

Numerical simulation

Integration uses fourth-order Runge–Kutta with Δt=0.05 ms. Default initial conditions are V(0)=−60 mV and w(0)=w∞(−60). Clicking the phase plane chooses a new initial state. Playback speed changes the rate of model time, while the integration step remains fixed.

Changing applied current preserves the evolving state and recorded history; changing another model parameter restarts the trajectory. Trace windows span 50–10,000 ms; CSV export contains the visible time window. Nullclines and equilibrium markers use the current parameter values.

See Chapter 14 of Cellular Biophysics and Modeling and the references below for the model’s derivation and phase-plane interpretation.